A Highly R290 heat pump compressor should be selected against the heating duty of the complete air-to-water system. Confirm the intended application, heating output at the required conditions, operating envelope, electrical supply and inverter compatibility. Then verify the exact model specification before requesting samples or placing a bulk order. A catalogue capacity or matching displacement alone does not establish suitability.
For OEMs and import buyers, a useful quotation starts with either a complete compressor model number or a clearly defined application requirement.

Already have a model to source? Send YUE the full Highly model number or a clear nameplate photo, quantity, destination and required shipping time. For a new application, include the target heating conditions. Request a Highly compressor quotation.
Why R290 Heat Pump Compressor Selection Matters in 2026
Table of Contents
ToggleEuropean heat pump demand has started to recover. EHPA reported that residential heat pump sales increased by 11% across the 12 European countries covered by its first-half 2026 figures. This is a market indicator for heat pump equipment, rather than a sales forecast for a particular compressor brand.
Refrigerant requirements also affect OEM purchasing decisions. From 1 January 2027, EU rules restrict F-gases with a GWP of 150 or more in specified equipment categories, including certain self-contained heat pumps and split air-to-water systems. Capacity thresholds and safety exceptions depend on the equipment category.
Highly’s 2026 exhibition information includes R290 heat pump compressors for the European market. For buyers evaluating these products, the next step is to establish which exact model fits the proposed system.
Sources: EHPA first-half 2026 sales release, European Commission equipment guidance and Highly’s 2026 exhibition report.
Start with the Correct Highly Application and Model Reference
Specify whether the compressor will serve space heating, space heating with domestic hot water, or a dedicated water-heating application. A product described broadly as a heat pump compressor still needs approval for its intended duty.
The 2023 Highly rotary compressor catalogue available on our website includes a DC inverter R290 section for floor heating and space heating. Examples of the model references shown there are:
| Catalogue model reference | Listed displacement | Listed rated speed |
|---|---|---|
| WHP03300PRK | 14.00 cc/rev | 3,600 rpm |
| WHP05500PSD | 22.60 cc/rev | 3,600 rpm |
| WHP10200PSD | 42.00 cc/rev | 3,600 rpm |
Use these entries to identify the relevant product family and request the current specification. The listed speed is a reference rating, not the complete approved speed range. Obtain the full ordering code, including any suffix, and confirm current availability separately.

Our Highly rotary compressor product page provides a starting point for brand enquiries. Include the complete model in your message so that the requested version can be checked.
Compare Heating Capacity at the Same Conditions
An enquiry for a “12 kW heat pump compressor” is incomplete unless it identifies where that output is required and whether the figure describes the compressor or the complete heat pump.
Separate the two kinds of performance data:
| Data being reviewed | Conditions to establish | What the buyer can assess |
|---|---|---|
| Compressor performance data | Refrigerant, evaporating and condensing temperatures, return-gas conditions, subcooling where applicable, speed and test method | Compressor output and electrical input at a defined refrigeration-cycle point |
| Complete heat pump test data | Outdoor air conditions, entering and leaving water temperatures, water flow, test standard and operating mode | Delivered heating output and efficiency of the assembled unit |
For example, A7/W35 commonly identifies an air-to-water unit rating with outdoor air at 7°C and leaving water at 35°C. A-7/W55 represents a different duty: outdoor air at -7°C and leaving water at 55°C. The full test definition also matters.
A catalogue rating cannot be relabelled as A-7/W55 output. Outdoor air temperature is not the compressor’s evaporating temperature, and leaving water temperature is not its condensing temperature. The OEM must establish the corresponding refrigeration conditions through its system design and validation.
Ask shortlisted suppliers for heating output and input power at comparable points and speeds. Check what electrical loads the efficiency calculation includes. Compressor heating COP, complete-unit COP and seasonal COP describe different assessment boundaries or periods.
For broader specification checks across applications, see our refrigeration compressor selection guide.
Check Low-Ambient Heating and Water Temperature Together
Define the required water-temperature schedule alongside the outdoor design conditions. An underfloor heating duty and a higher-temperature radiator duty can require different compressor operating points, even where the nominal heat pump capacity is similar.
For each proposed Highly R290 model, request a review of:
- Heating output at the required low-ambient duty.
- Permitted evaporating and condensing conditions at the selected speed.
- Input power, current and discharge-temperature limits.
- Restrictions affecting hot-water operation, defrost and mode changes.
An advertised minimum ambient temperature does not establish the heating output available there. Likewise, a maximum water temperature should be accompanied by its applicable ambient conditions and capacity information.
Where an EVI configuration is being considered, confirm the exact compressor version and required injection circuit. Compare the documented performance of the proposed configuration; EVI should not be assumed from the brand name or an inverter description.
Verify the Inverter Drive and Mechanical Integration
For an inverter model, identify the compressor and drive as a matched combination. State whether the enquiry is for the compressor alone or includes a drive, cables, sensors or other specified accessories.
The review should establish the drive model and parameter version, motor compatibility, supply voltage, communication requirements, speed limits and protection functions. Keep incoming mains frequency separate from motor operating frequency and shaft speed.
Mechanical integration also needs a drawing review. Compare mounting centres, overall height, suction and discharge connections, accumulator arrangement and terminal orientation with the proposed cabinet layout.

During prototype testing, the OEM should check oil return, liquid return, vibration and control behaviour across the intended operating range. Low-speed operation and transitions deserve attention as well as the nominal rating point. Follow the application requirements for the exact Highly model.
Comparing several model options? Send the proposed model list, duty points and drive requirements to YUE. Identify the specifications or documents you still need so they can be addressed in the enquiry. Send your model list for review.
Establish R290 System Requirements Before Approving Samples
R290 is propane, classified as an A3 refrigerant. Compressor selection therefore belongs within the safety assessment of the complete heat pump.
The equipment design must address the applicable refrigerant charge requirements, potential leak locations, ignition sources, component suitability and installation arrangement. Requirements vary with the product and destination market; a single charge-limit figure should not be applied to every air-to-water design.
A compressor’s supporting documents do not establish conformity of the finished heat pump. Identify which documents apply to the component and which require complete-unit assessment. Any change from an existing R32 or R410A design to R290 requires an appropriate system review, rather than approval based on similar capacity or mounting dimensions.
What to Include in a Highly R290 Heat Pump Compressor RFQ
Use the following information to make quotations easier to compare. If a field is unknown, mark it as unknown and attach the information you do have.
| RFQ field | Information to provide |
|---|---|
| Procurement route | Exact model sourcing, new OEM application, or review of an alternative |
| Compressor identification | Full model and suffix; nameplate photo if available |
| Heat pump application | Air-to-water space heating, heating with domestic hot water, or another stated duty |
| Heating requirement | Required output and the complete conditions at which it is needed |
| Temperature range | Design outdoor conditions and entering/leaving water temperatures |
| Electrical requirements | Destination supply voltage, phase and frequency; existing drive details if applicable |
| Drive and accessories | Compressor only, or a clearly defined requested package |
| Mechanical constraints | Available space, mounting drawing and connection requirements |
| Order details | Sample quantity, expected batch quantity and destination |
| Schedule and documents | Required shipping time and named technical or commercial documents |

Example of a New-Application Enquiry
The following is an illustrative brief, not a recommendation for any particular model:
We are evaluating a Highly R290 inverter compressor for an air-to-water heat pump. Our complete-unit heating target is 12 kW at A-7/W55. The design minimum ambient temperature is -15°C. We will provide the full air/water test conditions and refrigeration-cycle design points for compressor review. The equipment supply is 230 V, single-phase, 50 Hz. Please identify suitable model options for evaluation and clarify the drive scope, available technical documents, sample quantity options and delivery schedule. Destination: [country]. Expected batch quantity: [quantity].
For exact-model procurement, a shorter first message is sufficient: full model or nameplate photo, quantity, destination and required shipping time. Attach the existing specification when available.
Confirm the Supply Scope Before a Batch Order
Once the technical option has been reviewed, put the agreed model and ordering code into the quotation and purchase documents.
Confirm whether the price covers only the compressor or also a specified drive and accessories. Record the sample and batch quantities, packaging requirements, delivery terms, destination and agreed shipping schedule.
Identify the documents needed for your order early. Depending on the product and destination, these may include the model specification, outline drawing, available performance information, relevant component certification and agreed export documents. Confirm availability for the exact item instead of relying on a general brand statement.
For a new OEM application, complete the planned sample evaluation before approving repeat purchasing. If a model or drive version changes between the sample and batch stages, review that change before accepting it.

Frequently Asked Questions
Which Highly R290 compressor is suitable for a 12 kW air-to-water heat pump?
The unit rating alone is insufficient to select a model. Define the required heating output, air and water conditions, refrigeration-cycle points, supply and drive requirements. Review candidate performance data and validate the complete unit. Does the WHP model prefix confirm R290 compatibility?
No. Highly catalogue references include WHP models for different refrigerants and applications. Verify R290 approval against the complete model specification, including the relevant suffix. Can the compressor catalogue COP be used as the heat pump’s SCOP?
No. A compressor rating at one stated condition does not establish seasonal efficiency of the assembled heat pump. Use the applicable complete-unit assessment for the claimed result. Should I request a compressor together with an inverter drive?
State whether a drive is required and identify any existing controller. Confirm the proposed compressor-drive combination, parameters and interfaces for the exact application. Package availability and included items should be stated in the quotation. What should an importer send first to obtain a quotation?
Send the full model number or a clear nameplate photo, quantity, destination and required shipping time. For a new application, add the heating duty and operating conditions. State any sample, accessory or document requirements.
Request Your Highly R290 Heat Pump Compressor Quotation
YUE is a multi-brand compressor supplier. You can learn more through About YUE and view our compressor supply range.
To enquire about a Highly R290 heat pump compressor, send the complete model or nameplate photo, quantities, destination and required shipping time. For OEM selection enquiries, include the application and target operating conditions. Mention any samples, drives, accessories or specific documents you need so that availability and quotation scope can be checked.